Purpose of this article
This article is for the technical team that sends files to Scaler: how to connect to Scaler's SFTP server, upload a file and read the answer Scaler returns for it. File formats, file rules and onboarding requirements are in SFTP file delivery requirements.
Connection and access
Topic | Detail |
SFTP server, port 22 | EU: sftp.scalerglobal.com. AU: sftp.au.scalerglobal.com. Your login details name your region. |
Web upload page | EU: https://sftp-web.scalerglobal.com. AU: https://sftp-web.au.scalerglobal.com. |
IP addresses for your firewall | EU: 52.211.214.252, 108.133.63.191. AU: 13.236.104.127, 13.55.239.10. |
Login | One login per client and data provider. A login sees only its own folder. |
Authentication | SFTP accepts an SSH key only, never a password. The web upload page uses the username and password. |
Ways to upload | A scheduled export, any SFTP program (for example FileZilla, WinSCP or Cyberduck), or the web upload page |
Key changes | Send the new public key to integrations@scalerglobal.com. Scaler adds it, you confirm you can log in, then Scaler removes the old key. |
Rotate keys once a year, and whenever the person holding the private key leaves your organization.
Creating an SSH key pair
Run this on Mac, Linux or Windows PowerShell:
ssh-keygen -t ed25519 -C "scaler-sftp" -f scaler_sftpThis writes scaler_sftp, the private key you keep, and scaler_sftp.pub, the public key you send to Scaler. An RSA key also works.
Checking the server on first connection
The first time you connect, your SFTP program shows the server's key fingerprint and asks you to confirm it. Compare it with the values below. If it matches, confirm and connect. If it does not match, do not connect, and email integrations@scalerglobal.com.
Server | Key type | Fingerprint |
EU, sftp.scalerglobal.com | ED25519 | SHA256:jS0mCmG+o09Da+MUnzU9o+vyYGM9Ncy2i0Allqgjc/M |
EU, sftp.scalerglobal.com | RSA | SHA256:qbg1P/TWUCifOPZz5Ad8vIinHHchbi/uiI/nZ5TGmDA |
AU, sftp.au.scalerglobal.com | ED25519 | SHA256:Ow5xk5Cdwiy3i/6+yoNCIpBHRwb6eBrYtD5iPDjNd3k |
AU, sftp.au.scalerglobal.com | RSA | SHA256:jN5qpJK2oGGuyRP+Zkq+3uLZr81ZM6ekTTNVX0tFjzY |
Your program shows one of the two lines for your server, usually ED25519.
Folders
Folder | Purpose | You can |
inbox | Upload files here | Upload, list, download, overwrite |
landed | Scaler's copy of each file it picked up from inbox | List, download |
receipts | Scaler's answer for each file it read | List, download |
errors | Scaler's answer for each file it refused | List, download |
Upload files directly to inbox. Files cannot be deleted or renamed, and they stay in inbox after Scaler reads them. Every file in these four folders is deleted 90 days after it arrives there, so keep your own copy of anything you need for longer.
Uploading a file
By SFTP, from a scheduled export or an SFTP program
- Connect to your region's SFTP server on port 22 with your username and private key.
- Upload the file to
inbox.
- After a few minutes, read the answer in
receiptsorerrors.
On the web upload page
- Open your region's web upload page and sign in with your username and password.
- Open
inboxand upload the file.
- After a few minutes, open
receiptsorerrorsto read the answer.
Give every upload a new file name, for example companyname_2026-10.xlsx, so each file keeps its own receipt.
What you get back after each file
Every file gets one answer within minutes. One bad row does not stop a file: Scaler sets the row aside, stores the other rows and reports the row.
Outcome | What you find in your folder | What to do |
Processed | A receipt in receipts | Nothing |
Processed, some rows set aside | A receipt in receipts listing up to 100 set-aside rows, each with row number, column and reason | Correct those rows and upload the file again |
Identical file already received | A duplicate receipt in receipts | Nothing. The first upload's data is stored. |
Refused because of the file | An error file in errors explaining the problem | Fix the file and upload it again |
Problem on Scaler's side | An error file in errors saying the problem is on the Scaler side, with a reference | Nothing to fix in your file. Email the reference to integrations@scalerglobal.com. |
The receipt is a JSON file for your automation. The error file comes as JSON and as a text file for people.
Common reasons a row is set aside
Reason | Meaning | Fix |
row_unreadable | No Asset ID or Meter ID, or no value in Consumption, Redelivery To Grid, Production or Meter Reading | Fill the missing cell |
period_invalid | A date is empty, not yyyy-mm-dd, or End Date is before Start Date | Correct the date |
period_overlaps | The period overlaps another period of the same meter, already stored or in the same file | Send the row with the stored period's dates, or with the stored row's Record ID. To change a period stored without a Record ID, contact the Scaler client service team. |
value_invalid | A number holds commas, text or a unit | Write a plain number |
unit_unknown | Unit is empty or not recognized | Write the unit, for example kWh |
row_duplicate | The same meter and period appear twice in the file. Scaler keeps the later row. | Keep one row per meter and period |
meter_not_found, record_unstorable | Scaler could not store the row | Nothing to fix in your file. Email integrations@scalerglobal.com with the file name. |
Corrections, duplicates and re-sends
- A corrected row replaces the earlier value only when it has the same meter,
Start DateandEnd Date. A row with aRecord IDreplaces the earlier row with the same meter and ID, and can change its period too. Send the full corrected value, not the difference.
- Always use the same period boundaries. Without a
Record ID, a row for other dates that overlap a stored period does not replace the stored row: Scaler sets it aside asperiod_overlaps.
- An identical file sent again within 90 days stores nothing, and you get a duplicate receipt. A corrected file differs, so Scaler reads it.
- A file adds or updates data. It never removes data: a value missing from a later file stays in Scaler. To remove a value, contact the Scaler client service team.
- An upload under an earlier file name is read, and its receipt replaces the earlier receipt.
Troubleshooting and common mistakes
- No receipt or error file after 15 minutes β check the file sits directly in
inbox, then email integrations@scalerglobal.com with the file name and upload time.
- SFTP refuses the login β SFTP accepts the SSH key only. Check you use the private key that matches the public key you sent.
- The web upload page refuses the login β ask integrations@scalerglobal.com to reset the password.
- The error file says the header is not the Scaler template β the header must be the first row and include
Asset ID,Meter ID,Unit, and at least one ofConsumption,Redelivery To Grid,ProductionorMeter Reading.
- The error file says the problem is on the Scaler side β nothing to fix in your file. Email the reference to integrations@scalerglobal.com.
- Duplicate receipt and nothing stored β that exact file was already processed. Send a corrected file instead.
- A value still shows after you left it out of a file β files never remove data. Contact the Scaler client service team.
- Data stored but not visible in Scaler β the meter is not mapped yet. The client's admin maps it on the Automations page.
- A NEM12 file is refused as incomplete β the file has no
900end-of-file record. Write the export fully before you transfer it.
Contact
Logins, SSH keys, passwords, files without an answer and Scaler-side errors: integrations@scalerglobal.com. File format, scope and fees: the Scaler client service team.
Additional resources
- SFTP file delivery requirements: accepted files, file rules and onboarding checklists
- Automations & Integrations FAQ: common questions about automated data collection